SourcingAI

X ray protective

I have found results from20000+products and6000+suppliers aboutX ray protective

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Protective Glasses
Type: Protective Clothing
Type: X-ray Shield
X Ray Equipment
Protective Glass Plate
Surgical Supplies Materials
Type: X-Ray Equipment
Condition: New
Certification: CE
Application: Adult
Nature: Specialized Equipment
Feature: Un-waterproof
Usage Times: Non-Disposable
Customized: Customized
Gender: Female
Suitable for: Elderly
Usage: Polishing Material
Material: PVC
Applicable Departments: Dental Department
Imaging Diagnostic Equipment
Ethylene Oxide Sterilization
With Logo Printing
Style: Modern
Open Style: Sliding
Position: Exterior
Surface Finishing: Finished
Function: Security
Sound Insulation: 30
Screen Netting Material: Fiberglass
Veneer Wood: White Oak
Security Rating: B
Standard: JIS
Certification: ISO
Certification: RoHS
Certification: EEC
Certification: MSDS
Certification: ISO13485
Application: Child
Application: Aviation
Application: Electronics
Application: Industrial
Application: Medical
Application: Chemical
Shared Instrument Equipment
Specialized Instrument Equipment
Usage Times: Disposable
Customized: Non-Customized
Gender: Male
Suitable for: Children
Suitable for: Adult
Usage: Embedded Material
Dental Preventive Health Care Materials
Material: Latex
Material: Plastic
Material: Steel
Applicable Departments: Oral Surgery
Oral Department of Internal Medicine
Position: Interior
Function: Decoration
Standard: GB
Standard: DIN
Standard: BS
Standard: ASTM
Standard: AISI

Sourcing guidance for X Ray Protective

What are the core technical specifications to consider when sourcing X-ray protective clothing?

The most critical specification is the Lead Equivalence (Pb), typically ranging from 0.25mmPb to 0.5mmPb. For high-exposure environments like interventional radiology, 0.5mmPb is the standard. Additionally, you must choose between traditional lead, lead-lite, or lead-free (non-lead) materials. Lead-free options are preferred for modern procurement due to their lighter weight (reducing musculoskeletal strain) and environmentally friendly disposal.

Which international compliance standards must X-ray protective products meet?

Products must strictly adhere to IEC 61331-1:2014 (determination of attenuation properties) and IEC 61331-3:2014 (protective clothing and eyewear). For the US market, FDA registration is mandatory, while the EU market requires CE marking (PPE Regulation 2016/425). Ensure the supplier provides a Declaration of Conformity and valid ISO 13485 certification for medical device quality management.

How can a buyer verify the protective integrity and durability of the equipment?

Request third-party attenuation test reports that verify the shielding effectiveness at different kVp levels (e.g., 60kV, 80kV, 100kV). For durability, check the outer fabric material; it should be waterproof, antibacterial, and easy to disinfect (typically PU or Oxford fabric). Ask the supplier about the internal multi-layer structure, as multiple thin layers offer better flexibility and crack resistance than a single thick layer.

What are the usage scenarios and functional requirements for different X-ray accessories?

Usage varies by clinical need: Thyroid shields are essential for protecting the sensitive thyroid gland; Gonad shields are used for patient protection; and Lead glass/mobile barriers are required for structural shielding. For B2B buyers, ensure that ergonomic designs (such as vest-and-skirt styles) are prioritized for staff who wear the gear for extended periods to distribute weight evenly.

Cross-Border Procurement Risks and Strategies for Radiation Protection

How can I mitigate the risk of receiving sub-standard shielding materials?

Always request a pre-shipment inspection (PSI). You can hire a third-party agency to perform a random X-ray flaw detection test on the batch to check for internal cracks or 'pinholes' in the lead rubber. On Made-in-China.com, prioritize Audited Suppliers who have undergone on-site verification of their production capabilities.

What are the key negotiation points when dealing with medical-grade suppliers?

Focus on warranty periods (typically 12-24 months) and after-sales replacement policies for core material degradation. Negotiate for customized labeling and sizing (Asian vs. Western sizing differs significantly). For bulk orders, aim for a 15-20% discount when exceeding 100 sets, and request free samples of the raw shielding material for independent lab testing.

What are the logistics and customs precautions for shipping lead-based products?

Lead products are extremely heavy, which significantly impacts air freight costs. Sea freight (LCL or FCL) is usually the most economical method. Ensure the Harmonized System (HS) Code 9022.90 is used correctly. Be aware that some countries have strict environmental regulations regarding lead imports; ensure all packaging is robust to prevent deformation of the protective core during transit.

How do I ensure transaction security for high-value medical equipment orders?

Utilize Secured Trading Services provided by Made-in-China.com to ensure payment is only released after the goods have been shipped and the shipping documents are verified. Avoid direct wire transfers to unknown accounts; always use official corporate bank accounts listed on the platform to prevent fraud.