Liquid cooling system

I have found results from200000+products and70000+suppliers aboutLiquid cooling system

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Water-Cooled
Type: Air-Cooled
Type: Li-ion Battery
Type: Lithium-Ion Batteries
Type: Flotation Machine
Cycle Life: 6000 Cycles
Cooling Water: Industrial Water
System Type: Closed System
Fans Species: Frequency Fan
Noise Level: Low
Certification: ISO
Condition: New
Fast Installation: Fast Installation
Feature: Flexibly Combinable
Material: Container
Commercial Complex Peak Shaving
Standard Container (20ft/40ft)
Energy Capacity: 100kWh-500kWh
Power Configuration: 100kW-250kW
Full Liquid Cooling (Temperature Difference ≤3℃)
Rechargeable: Yes
Size: Large
Specification: Normal
Usage: Electric Power
High Discharge Rate
Shape: Square Battery
Electrolyte: Li-ion
Nominal Voltage: 768V
Weight: 2.6t
Application Fields: Welding
Unit Structure: Integral
Compressor Number: 1
Purpose: Gas Storage
Method: Combined Treatment
5000 Cycles (80%DOD)
8000 Cycles (80%DOD)
Cycle Life: 8000 Cycles
Fans Species: Double-speed fan
Noise Level: Ultra Quiet
Certification: CE
Certification: RoHS
Certification: UR
Certification: CCC
Certification: API
Certification: CB
Feature: Leak Proof
Feature: Moisture Proof
Application: Industrial
Application: Commercial
Data Center Backup Power
PV Supporting Energy Storage
Installation: Fixed
Installation: Cabinet Floor-Mounted
Power Configuration: 250kW-500kW
Cooling Method: Air-cooled
Rechargeable: Chargeable
Usage: Industrial
Nominal Voltage: 1331.2V
Nominal Voltage: 400V
Nominal Voltage: 230V/400V
Application Fields: Electronic
Application Fields: Chemical

Sourcing guidance for Liquid Cooling System

What are the key technical specifications to evaluate when sourcing a liquid cooling system for industrial or IT applications?

Buyers must prioritize Thermal Design Power (TDP) ratings to ensure the system can dissipate the heat generated by the target hardware. Key components to inspect include the pump flow rate (measured in L/h), radiator material (copper offers better thermal conductivity than aluminum), and coolant compatibility. For enterprise environments, ensure the system supports redundant pump configurations and features leak detection sensors to prevent catastrophic hardware failure.

Which international compliance standards are mandatory for liquid cooling systems in cross-border trade?

Products must adhere to CE (Europe) and FCC (USA) certifications for electromagnetic compatibility. Since these systems contain fluids, RoHS and REACH compliance are essential to ensure no hazardous substances are present. For high-pressure industrial systems, verify adherence to the Pressure Equipment Directive (PED) or equivalent local safety standards to ensure the integrity of hoses and fittings under stress.

How can a buyer verify the long-term reliability and maintenance requirements of these systems?

Request MTBF (Mean Time Between Failures) data for the pumps, which should ideally exceed 50,000 to 100,000 hours. Inquire about the evaporation rate of the coolant and whether the system is a Closed-Loop (AIO) or an Open-Loop design; AIO systems are generally maintenance-free for 3-5 years, while open loops require bi-annual fluid flushes and PH level checks to prevent corrosion and biological growth.

What customization options should B2B buyers look for to ensure system integration?

Suppliers should provide custom cold plate designs to fit specific chip architectures and variable hose lengths with quick-disconnect couplings (QDCs) for modularity. Ensure the supplier can provide PWM (Pulse Width Modulation) control compatibility for fans and pumps to allow for dynamic cooling based on real-time thermal loads.

Cross-Border Procurement & Risk Management for Liquid Cooling Systems

What are the specific shipping risks associated with liquid-filled cooling units?

Shipping liquids is classified under sensitive cargo by many carriers. To avoid customs delays or rejections, ensure the supplier provides a Material Safety Data Sheet (MSDS) and a Non-Hazardous Liquid Declaration. For air freight, systems should ideally be shipped drained of coolant to prevent pressure-related leaks, or use UN-certified leak-proof packaging if pre-filled.

How can I mitigate the risk of receiving defective units in a bulk order?

Implement a Pre-Shipment Inspection (PSI) protocol where a third party performs a 100% pressure test on a sample of the units to check for leaks. Use Made-in-China.com's Secured Trading services to ensure that payment is only released once the quality inspection report is verified and the goods are confirmed to meet your technical specifications.

What strategies should be used when negotiating with liquid cooling manufacturers?

Focus negotiations on warranty terms and spare parts availability. Aim for a 2-3 year replacement warranty that covers not just the unit, but also potential damage to connected hardware caused by manufacturing defects (leakage). Request tiered pricing based on annual volume commitments rather than single-order quantities to secure a lower Unit Price.

How do international trade policies affect the sourcing of cooling components?

Be aware of anti-dumping duties or specific tariffs on aluminum and copper components depending on your country's trade relationship with the manufacturing hub. Always verify the HS Code (typically 8419.50 or 8473.30) with your customs broker to accurately calculate the Total Landed Cost, including import duties and VAT.