Hplc vials
I have found results from10000+products and4000+suppliers aboutHplc vials
Alwsci High Recovery Gc/HPLC Autosampler 1.5ml Clear Glass Crimp Vial
Alwsci New Arrival HPLC 2ml Amber Glass Qr Code Vial
Alwsci 9-425 HPLC PP Vial Micro Insert IC Testing Laboratory Glassware
Lab Use 2ml Chromatography Vials Borosilicate Glass Autosampler Vial HPLC Vial
1.5ml Flat Glass HPLC Sample Vials with 2ml Chromatography Lab Consumables
2ml 9mm Short Thread Glass Vial Screw HPLC Autosampler Vial V923/V927
Lab 4ml Glass Clear HPLC Vial with 13-425 Plastic Screw Cap and Septa V1317 100PCS/Pack
Wholesale Amber 11mm Snap Ring 2ml HPLC Autosampler Vial
2ml Lab Liquid Chromatography Gc Amber Glass HPLC Autosampler Vials
HPLC Vials Screw Glass Bottle with Clear and Amber
Amber Clear 1.5ml 2ml HPLC Chromatography Autosampler Vials
1.5ml 2ml HPLC Autosampler Chromatography Amber Septa Glass Vials
2ml Clear Borosilicate Glass HPLC Autosampler Vials
Wholesale Chromatographic Autosampler Bottle High Quality 2ml Small Screw Top Glass Sample HPLC Vial
Laboratory Sample Bottles HPLC Vials 1.5/2ml Chromatography PP Autosample Vial Kit
9-425 2ml Autosampler Glass HPLC LC Gc Chromatography Vials
Lab Use 2ml Chromatography Vials Borosilicate Glass Autosampler Vial HPLC Vial
300UL Lab 9-425 Screw Autosampler Micro-Vial Integrated Inserts with Label for HPLC
Clear Transparent 2ml Autosampler Vials with Caps Chromptochrpy HPLC Vials Clear Sample Vial with Screw Caps
Manufacturing 10ml 20ml HPLC Vials Chromatography Autosampler Vials Laboratory Detection Headspace Vials
Sourcing guidance for Hplc Vials
How to choose the correct glass type for HPLC Vials?
For high-performance liquid chromatography, always prioritize USP Type I Borosilicate Glass. This material is essential because it has a low expansion coefficient and high resistance to chemical leaching, ensuring that the glass does not react with your samples or solvents. For light-sensitive compounds, select Amber glass to provide protection from UV degradation, while Clear glass is standard for most other applications.
What are the key considerations for selecting Septa and Caps?
The choice of septa is critical for maintaining sample integrity. PTFE/Silicone septa are the industry standard due to their excellent chemical resistance and resealability. If you are using an autosampler with a thin or fragile needle, opt for Pre-slit septa to prevent needle damage and vacuum formation. For the caps, Screw caps offer a reliable seal for general use, while Crimp caps are preferred for volatile samples to ensure a gas-tight environment.
How do I ensure compatibility with my Autosampler?
Dimensions are the most vital factor for technical compatibility. The standard size is 12x32mm (2ml), but you must verify the neck finish: 9-425 (short thread) is the most common for modern autosamplers like Agilent or Waters, whereas 8-425 (standard thread) or 11mm Crimp/Snap finishes may be required for older or specific models. Using the wrong neck finish can lead to mechanical failure or needle misalignment.
What quality standards and certifications should I look for?
To ensure consistent analytical results, source from suppliers who provide Batch Traceability and are ISO 9001 certified. For high-sensitivity work (LC-MS or GC-MS), request Certified Vials that have been tested for cleanliness and background interference. Ensure the products meet USP (United States Pharmacopeia) standards to guarantee the purity of the glass and the absence of contaminants like ions or plasticizers.
Cross-Border Purchasing Considerations for HPLC Vials
How can I mitigate the risk of breakage during international shipping?
Glass vials are fragile and prone to damage during long-transit cross-border shipping. Ensure the supplier uses double-wall corrugated export cartons and internal plastic tray packaging (shrink-wrapped) to prevent glass-to-glass contact. On Made-in-China.com, you can request the supplier to provide photos of the palletization and reinforcement before the goods leave the warehouse.
What are the strategies for negotiating with laboratory consumable suppliers?
Since HPLC vials are high-volume consumables, focus your negotiation on Annual Volume Pricing rather than single-order pricing. Ask for tiered discounts (e.g., 100+ packs vs. 500+ packs). Additionally, negotiate for free samples (10-20 units) to test compatibility with your specific autosampler and solvent chemistry before committing to a bulk purchase.
How do I ensure transaction security and quality alignment?
Utilize Secured Payment services provided by platforms like Made-in-China.com to ensure your funds are protected until the goods are delivered. For large orders, it is highly recommended to hire a third-party inspection service to conduct a 'Pre-shipment Inspection' (PSI) to verify the dimensional accuracy and cleanliness of the vials, reducing the risk of receiving sub-standard laboratory supplies.
What are the logistics and customs precautions for medical/lab glassware?
Verify the HS Code (typically 7017.90) for laboratory glassware to determine the correct import duties in your country. Ensure the Commercial Invoice and Packing List clearly state 'Laboratory Use Only' to avoid delays associated with medical device regulations (like FDA or CE) if the vials are not intended for clinical diagnostic use. For shipping to the US or Europe, Sea Freight is most economical for bulk, but Air Express is safer for smaller, high-value certified vial orders.




























