Hplc system
I have found results from60000+products and20000+suppliers aboutHplc system
Biobase HPLC System High Performance Liquid Chromatography
Biobase Pharmacy Testing HPLC System with Oven Liquid Chromatography
Chromatograph Machine HPLC Systems High Performance Liquid HPLC Chromatography
High Quality Photochemical Derivatization System for HPLC Liquid Chromatography
Advanced Analytical HPLC System for Precision Gradient Elution
Advanced HPLC System for Accurate Environmental Monitoring Solutions
Analytical HPLC System LC-500 for Routine Laboratory Analysis
Wook-500 Second-Class HPLC Derivatization System for Accurate Analysis
LC-500q High Performance Liquid Chromatography HPLC System with UV Detector and High Pressure Constant Current Pump
Preparative HPLC System with Dac Column for Natural Product Purification, Herbal Extract Isolation and Compound Separation
100MPa High Pressure HPLC System for Environmental Water Analysis with UV Detector for Lab & School
Wook-500 HPLC Post-Column Derivatization System for Fluorescence Enhancement
Gradient HPLC System for Laboratory Research and Method Development
Wook-500 HPLC Post-Column Derivatization System for Amino Acid Analysis
Rapid Prep HPLC System for Natural Products 200~400nm, Mg to Gram Purification, Auto Fraction Collector
Aiyi HPLC High Performance Liquid Chromatography with Lsocratic and Gradient System
High Performance Liquid Chromatography Binary Gradient HPLC System with UV Detector
Laboratory HPLC High Performance Liquid Chromatography System
Laboratory Machine High Performance Liquid Chromatography HPLC System
Variable Wavelength Detector Ion Chromatography HPLC System with Pid Control
System with 50dac Preparative HPLC Lab Equipment
High Quality Preparative Purify HPLC System for Separation Column
100ml Baniry System with 50dac Preparative HPLC
Manufacturer 300dac Purification HPLC System for Column Liquid Chromatography
11 Tetracycline Antibiotics Residue Detection HPLC System
Sourcing guidance for Hplc System
What are the key technical specifications to consider when selecting an HPLC system for industrial or laboratory use?
When sourcing an HPLC system, you must prioritize pump precision and pressure ratings. For standard HPLC, a pressure limit of 400-600 bar is typical, while UHPLC requires 1000+ bar. Ensure the flow rate accuracy is within ±0.1% to guarantee reproducible retention times. Additionally, evaluate the detector sensitivity (LOD/LOQ) and the injection volume precision (RSD <0.5%) of the autosampler to ensure high-quality analytical data.
Which detector types are most suitable for different application scenarios?
The choice of detector depends on your analytes. A UV-Vis or PDA (Photodiode Array) detector is the industry standard for compounds with chromophores. For compounds lacking UV absorption, such as sugars, an RID (Refractive Index Detector) or ELSD (Evaporative Light Scattering Detector) is necessary. For high-sensitivity environmental or pharmaceutical testing, look for systems compatible with Mass Spectrometry (LC-MS) interfaces.
What compliance standards and certifications are mandatory for international procurement of analytical instruments?
To ensure legal and safe operation, the system must carry the CE mark for European markets or UL/ETL certification for North America. For pharmaceutical applications, the software must be compliant with FDA 21 CFR Part 11, providing full audit trails and electronic signatures. Ensure the supplier provides IQ/OQ/PQ (Installation, Operational, and Performance Qualification) documentation to meet GxP requirements.
How does the modular design of an HPLC system impact long-term maintenance and scalability?
A modular HPLC design is highly recommended as it allows for independent upgrades of the pump, detector, or autosampler without replacing the entire unit. This significantly reduces long-term maintenance costs and downtime, as individual components can be serviced or swapped easily. Ensure the supplier offers backward compatibility for columns and consumables like seals and lamps.
Cross-Border Procurement Strategy for HPLC Systems
What are the primary risks when importing high-precision analytical instruments like HPLC?
The greatest risks involve damage during transit and customs clearance delays due to improper documentation. HPLC systems contain sensitive optics and high-pressure components; therefore, you must insist on vacuum-sealed anti-static packaging and wooden crate reinforcement. Ensure all HS Codes (typically 9027.20) are correctly declared to avoid heavy fines or seizures.
How should buyers negotiate with suppliers on Made-in-China.com to ensure transaction security?
Utilize the Secured Trading Service on Made-in-China.com to protect your payment until the goods are verified. Negotiate a staged payment plan (e.g., 30% deposit, 70% after successful Pre-Shipment Inspection (PSI)). Request a live video demonstration of the specific unit's performance test results before final balance payment to ensure the hardware meets the promised specs.
What logistics and shipping methods are recommended for sensitive laboratory equipment?
For high-value instruments like HPLC, Air Freight is preferred over sea freight to minimize the duration of exposure to humidity and mechanical vibration. Request 'Fragile' and 'Do Not Stack' labeling in both English and the destination language. It is critical to purchase Full Cargo Insurance covering the total invoice value plus 10% to mitigate financial loss from accidental damage.
How can buyers ensure effective after-sales technical support across borders?
Before purchasing, confirm if the supplier provides remote technical support via AR or video conferencing. Ask for a guaranteed response time (e.g., within 24 hours). For enterprise-level buyers, negotiate the inclusion of a spare parts kit (including plungers, seals, and lamps) in the initial order to prevent operational halts while waiting for international shipping of consumables.