Fluorescent lamps
I have found results from10000+products and6000+suppliers aboutFluorescent lamps
1200mm 110W 120W 220W UV Light Lamp UV Fluorescent Lamp 253.7nm UV Lamp
Fluorescent Light Fixture T9 PC Tube 14W/19W/24W 100lm/W 3CCT 215mm/300mm/400mm
UVA Gel Nail Polish Beauty Cure Dry Fluorescent Lamp UV UV Lamp
RoHS Approved Fixture Yh15 (E) T5/T8 IP65 Tri-Proof Fluorescent Lamp (YH15) with Low Price
20W Black Wood's Violet Lamp Rechargeable Fluorescent Detection Lamp UV365 Detection Lamp
Hpm175W Mercury Lamp High Pressure Fluorescent Lamp
T5 T8 T12 Blue UV Fluorescent Lights Blue Lamp Medical Therapy Jaundice Lamp
365nm T8 18W 20W Ultraviolet Light Fluorescent Tube Electric Insect Fly Mosquito Killer Lamp
4W 6W 8W Ultraviolet Light Ultraviolet Lamp Mosquito UV T5 UVA Insect Killer Fluorescent Lamps
20W 30W 40W Blue UV Fluorescent Lights Blue Lamp Medical Therapy Jaundice Lamp
High Quality T12 20W 40W 65W 75W 100W 125W Fluorescent Lamps
T5 T8 High Irradiance Fluorescent Lamp Artificial Weathering Q-Lab Tube
UV Fluorescent Lamp Artificial Weathering High Quality Tube 313nm T8 T12 Q-Lab Tube
T5 T8 UV Fluorescent Lamp Artificial Weathering Aging Base G5 G13 OEM
UVA Fluorescent Lamp Artificial Weathering High Quality Tube T12 Q-Lab
Ce UL 20W 24W E27 B22 Spiral Compact Fluorescent Lamps
9W - 105W Flower Warehouse Compact Fluorescent Lamps
Sourcing guidance for Fluorescent Lamps
What are the key technical specifications to consider when sourcing fluorescent lamps for commercial use?
When evaluating fluorescent lamps, prioritize Luminous Efficacy (lm/W) to ensure energy efficiency. Key specs include Color Rendering Index (CRI), where a value of Ra ≥ 80 is standard for offices, and Correlated Color Temperature (CCT), typically ranging from 3000K (Warm White) to 6500K (Daylight). Additionally, verify the Ballast Compatibility (Electronic vs. Magnetic) and the Rated Average Life, which should ideally exceed 15,000 to 20,000 hours for T5 or T8 tubes.
Which international compliance standards are mandatory for importing fluorescent lamps?
Fluorescent lamps contain mercury, making compliance critical. Ensure products meet RoHS (Restriction of Hazardous Substances) to limit heavy metals and CE (for EU) or UL/ETL (for North America) for electrical safety. For the US market, Energy Star certification is vital for rebates, while IEC 61195 ensures double-capped fluorescent lamps meet safety requirements. Always request a Material Safety Data Sheet (MSDS) due to the mercury content.
How do T5, T8, and T12 fluorescent lamps differ in terms of procurement strategy?
T5 lamps are the most efficient and compact, ideal for new installations requiring high output. T8 lamps are the current industry standard for retrofitting, offering a balance of cost and performance. T12 lamps are largely phased out due to inefficiency; sourcing them is discouraged unless for specific legacy maintenance. Focus your procurement on T5 and T8 high-frequency (HF) tubes to align with modern energy-saving building codes.
What quality control measures should be implemented during the sourcing process?
Request a Light Decay Test Report to see how brightness holds up over time. Conduct a Vacuum Integrity Check to ensure no gas leakage. For bulk orders, perform a Switching Cycle Test (on/off endurance) and verify Color Consistency (SDCM < 5) across different batches to avoid visible variations in light hue when installed in the same room.
Cross-Border Procurement & Risk Management for Fluorescent Lamps
What are the primary risks when shipping fluorescent lamps internationally?
The biggest risk is fragility and hazardous material classification. Fluorescent tubes are prone to breakage; therefore, 5-layer corrugated outer cartons with EPE foam internal bracing are mandatory. Because they contain mercury, they may be classified as Category 9 Miscellaneous Dangerous Goods in some jurisdictions, requiring specific labeling and higher freight costs. Always clarify the UN Number for hazardous shipping with your forwarder.
How can I negotiate better terms with suppliers on Made-in-China.com?
Focus on Total Cost of Ownership (TCO) rather than just unit price. Negotiate for a 1-2% defect allowance or spare units included in the shipment to cover potential transit breakage. For long-term contracts, request Price Protection Clauses against fluctuations in phosphor or glass raw material costs. Use the Trade Resources on Made-in-China.com to verify the supplier's Audit Reports and production capacity before depositing funds.
What transaction security tips should be followed for large lighting orders?
Always utilize Secured Payment services provided by the platform to ensure funds are only released upon proof of shipment. For orders exceeding $10,000, hire a third-party inspection agency (like SGS or Intertek) to perform a Pre-Shipment Inspection (PSI). Ensure the Proforma Invoice (PI) explicitly states the mercury content per lamp and the specific warranty period (typically 2-3 years).
How do international trade policies affect the sourcing of fluorescent lamps?
Many countries are implementing Minamata Convention on Mercury guidelines, which aim to phase out mercury-added products. Check your local import tariffs and anti-dumping duties, especially for Chinese-made lighting in the EU or US. Ensure the supplier provides a Certificate of Origin to benefit from any applicable Free Trade Agreements (FTAs) that might reduce customs duties.