Current transformer clamp
I have found results from20000+products and7000+suppliers aboutCurrent transformer clamp
50A Clamp-on Type Current Sensor Current Transformer
0.2 Accuracy 0.333V Output Clamp on Sensor Probe Current Transformer
10mv Rated Output 2% Accuracy Clamp on Current Transformer Probe Sensor
0.1A-1000A Clamp on Sensor Current Transformer From China
10Hz 100kHz Clamp on Sensor Current Transformer with Clamp on 600A/5A
500A  AC 600V Clamp Probe Clamp on Current Transformer
5-1000A 0.1 Accuracy Clamp-on Meters Current Transformer
Custom Made Control 12V 1000A Transformers Electric CT Current Transformer Clamp Meters
High Voltage Current Limiting Fuse Clamps for Transformer Protection
UL CE Sct-T16 100A 50mA White Color Clamp on Current Transformer
UL2808 Xoba Xh-Sct-T06 T12 T18 T20 Clamp on CT Sensor Split Core Instrument Current Transformer
Customized 50A/50mA Clamp on Current Transformer for Control System Clip-on CT
16mm Hole Xh-Sct-T16-20A/0.333V Split Core CT Current Transformers for IoT CT Current Clamp with UL
Q125 High Precision Clamp on Current Transformer Current Sensor
Permalloy Core Clamp Meter Clamp on Current Transformer Current Sensor
High Current Sensor 3000/5A 150mm Jaw Clamp on Current Transformer
S150 Large Jaw 150mm Cable Fault Location Supermalloy Current Transformer Clamp
CE and RoHS of Clamp on Current Transformer with 1000A/1A
Clamp on of Current Transformer 2500A/5A and 0.5class
100A/1V Electrical Instument Clamp on Current Transformer
Clamp on Current Transformers with Heyi Asct Kct-6 5A/2.5mA Cl: 0.5
Kct-16 150A/30mA Cl: 0.5 Heyi Asct Clamp on CT Rogowski Coil Split Core Current Transformers
Kct-16 100A/20mA Cl: 0.5 Heyi Asct Clamp on CT Rogowski Coil Split Core Current Transformers
Kct-50 800A/333mv Cl: 0.5 Heyi Asct Clamp on CT Rogowski Coil Split Core Current Transformers
Weatherproof Jgwd-7 Transformer Base Clamp with Anti Oxidation Coating Finish Set
Sourcing guidance for Current Transformer Clamp
What are the key technical specifications to consider when selecting a Current Transformer (CT) Clamp?
When sourcing CT clamps, you must prioritize Accuracy Class (e.g., Class 0.5, 1.0, or 3.0) to ensure precise measurement. Key electrical parameters include the Transformation Ratio (e.g., 1000:1 or 3000:1), Rated Burden, and Phase Shift. For physical compatibility, verify the Internal Diameter (Jaw Opening) to ensure it fits the primary conductor size, and check the Frequency Range (typically 50Hz/60Hz) to match your local power grid.
Which safety and compliance standards are mandatory for international trade of CT clamps?
To ensure operational safety and market access, products must comply with IEC 61010-1 and IEC 61869-2 (specific to current transformers). For the North American market, UL certification is essential, while CE marking and RoHS compliance are required for the European Union. Ensure the device has a sufficient Overvoltage Category rating (CAT III or CAT IV) based on the intended installation environment to prevent catastrophic failure during voltage spikes.
How do different core materials affect the performance of a Current Transformer Clamp?
The core material directly impacts sensitivity and linearity. Silicon Steel cores are cost-effective for standard industrial power monitoring. However, for high-precision applications or low-current measurements, Permalloy (Nickel-Iron alloy) or Nanocrystalline cores are preferred due to their high permeability and minimal phase error. For high-frequency AC measurements, Ferrite cores are the industry standard.
What usage scenarios dictate the choice between a split-core and a solid-core CT clamp?
Split-core CT clamps are ideal for retrofitting and energy audits because they can be installed without disconnecting the primary circuit, significantly reducing labor costs and downtime. Solid-core CTs are generally more accurate and less expensive but are restricted to new installations where the wire can be threaded through the window during assembly.
Cross-Border Procurement Strategy & Risk Management
How can I mitigate the risk of receiving substandard electrical components?
Always request a Type Test Report from an independent laboratory before placing a bulk order. Utilize Made-in-China.com's 'Audited Supplier' reports to verify the manufacturer's production capacity and quality control systems. It is highly recommended to arrange a Pre-shipment Inspection (PSI) to verify that the secondary output protection (like Zener diodes) is functional, preventing high-voltage hazards if the secondary circuit opens.
What are the best practices for negotiating with CT clamp suppliers?
Focus on Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for customized lead wire lengths and connector types (e.g., BNC, 3.5mm jack, or bare wires) to be included in the price. For high-volume orders, aim for a 15-20% discount and request Gold-plated connectors to ensure long-term contact reliability in humid environments.
What shipping precautions should be taken for sensitive magnetic components?
CT clamps contain sensitive magnetic cores that can be damaged by physical shock or strong external magnetic fields. Ensure the supplier uses anti-static packaging and shock-absorbent foam inserts. For air freight, confirm that the packaging complies with IATA Magnetized Material regulations if the magnetic field strength exceeds specific limits, though most small CTs are exempt if packed correctly.
How do I ensure transaction security when dealing with overseas suppliers?
Use Secured Payment services provided by reputable B2B platforms like Made-in-China.com to ensure funds are only released upon confirmation of delivery. Avoid direct wire transfers to private accounts. For large enterprise orders, consider using a Letter of Credit (L/C) to align payment with strict quality and documentation milestones.





























